A Cleaner Start for Your Biofilter.
Runoff brings more than water to a rain garden or bioswale. PRETX-LT intercepts sediment, floatables and debris at the inlet, helping protect the treatment area beyond it. R.H. Moore can help evaluate the curb connection, downstream interface and cleanout access for your Florida project.
Give Incoming Debris a Defined Collection Point
PRETX-LT is an inlet-based pretreatment option for new construction and retrofit green infrastructure. Its precast concrete structure and galvanized steel grating provide an accessible first stage ahead of downstream treatment.
Rain Gardens & Bioretention
Evaluate pretreatment where pavement runoff enters a planted treatment area.
Bioswales & Curbside Landscapes
Coordinate the collection point with the curb cut, surface grades and receiving swale.
Commercial & Municipal Sites
Consider expected debris loading and the maintenance route when reviewing parking areas, streetscapes or other paved catchments.
Screen, Separate, Settle & Discharge
01 / Screen Incoming Debris
The debris grate screens larger material as runoff enters.
02 / Retain Floatables
A baffle helps retain floating and lightweight material within the unit.
03 / Settle & Pass Flow Onward
A sediment weir promotes settling before water continues toward the biofilter. The unit pretreats water-quality flows and provides for larger-event bypass in the selected design.
PRETX-LT is the pretreatment stage. Downstream biofiltration or infiltration provides the next part of the site’s water-management strategy.
Understand the Inlet and Downstream Connection


Connect Curb Flow to the Treatment Area
The published PRETX-LT detail shows edge-of-pavement and gutter inflow through curb cuts and tipped pavement. Review the complete inlet-to-outlet elevation chain before fixing the structure location.
At the Inlet
Coordinate gutter flowline, pavement tip-down, curb transitions and grate elevation so runoff enters the intended collection point.
At the Outlet
Match the discharge opening and downstream media elevation. Include the specified stone apron and keep the discharge path clear.
Around the Structure
Check utilities, excavation space, grate/cover access and room for vacuum-truck service. Use current regional fabrication dimensions.
Check Treatment, Conveyance & Bypass
The PRETX family sizing guide includes an LT entry. Published capacities depend on head, inlet restrictions and free-discharge assumptions; acreage guidance is conditional.
Water-Quality Flow
Identify the flow requiring pretreatment and the receiving practice. Peak conveyance capacity is not the same as treatment capacity.
Head & Tailwater
Provide upstream grades and downstream water levels. Confirm that available elevation supports the proposed flow path.
Model & Detail
Reconcile the guide with the current LT drawing and regional structure before ordering. Open the Family Sizing Guide (PDF) →
What Does Your Team Need Next?
Engineers & Landscape Architects
Bring the drainage concept and landscape plan together. Identify required treatment flow, media elevations, overflow and access.
Contractors & Estimators
Share the selected detail, quantity, excavation conditions and schedule. Clarify grate, concrete, internal components and connection scope.
Owners & Maintenance Teams
Review where debris will collect and how it will be removed. Identify who inspects the inlet and who maintains the downstream practice.
Protect the Inlet and the Biofilter During Construction
Confirm the Layout
Verify utilities, dimensions and elevations against approved plans before placing the structure.
Control Construction Sediment
Sequence upstream site work and stabilization before connecting the treatment facility. Protect the adjacent biofilter from construction loading and contamination.
Complete the Handoff
Check internal components, access, outlet clearance and cleanup. Record the installed configuration and hand over the applicable maintenance instructions.
Keep Access and Flow Paths Clear
Convergent describes vacuum-truck-accessible maintenance for PRETX-LT. Ask RHM for instructions applicable to the supplied unit; the linked family O&M guide provides an inspection framework.
Inspect
Check incoming debris, sediment accumulation, screen condition and drainage after storms. Set the inspection frequency for actual loading.
Remove Accumulation
Plan safe equipment access and cleanout before the inlet becomes restricted. Follow the manufacturer’s procedures for the selected configuration.
Maintain Both Stages
Pretreatment concentrates some maintenance upstream; it does not eliminate care of the biofilter. Review the PRETX Family O&M Guide →
PRETX-LT FAQs
Is PRETX-LT a complete biofiltration system?
No. It is an upstream pretreatment component. Evaluate the downstream treatment practice separately against the project requirements.
Can it fit an existing curb cut?
A retrofit may be possible. Review grades, utilities, structure footprint and downstream connection before deciding whether the existing opening can be used.
Is PRETX-LT interchangeable with PRETX Curb or Drop?
Use the detail for the selected configuration. The inlet geometry, elevations and connection requirements need review; do not substitute one drawing for another.
Does Lite mean lightweight or traffic-rated?
The PRETX-LT name is not a handling-weight or loading specification. Confirm lifting weight, frame/grate loading and placement requirements in the project submittal.
Will it eliminate clogging or maintenance?
It helps intercept material before it reaches the treatment bed. Performance still depends on proper sizing, installation and regular cleanout.
What information is needed for pricing?
Send the Florida project location, plans, quantity, selected detail, grades, flow information, downstream practice and delivery timing.
Start With the Correct Detail
LT Configuration
Family Reference
PRETX Sizing Guide (PDF) →
PRETX O&M Guide (PDF) →
PRETX Family Brochure (PDF) →
Family references cover multiple configurations. Confirm applicability and the current revision with RHM before incorporating them into project documents.
Discuss PRETX-LT With R.H. Moore
Have a curbside biofilter concept or a retrofit to evaluate? Share the plans and site constraints so we can help focus the next technical discussion.
Send What You Have
Project location, inlet layout, pavement and outlet elevations, drainage information, downstream practice, quantity and timing.
Know the Next Step
RHM can clarify the requirements, coordinate manufacturer review where needed and develop a project-specific recommendation or pricing request.