Hydrodynamic Separation | Stormwater Treatment Solutions

The Right Separation System. Built Around Your Site.

Sediment, trash and floating pollutants need a capture strategy that fits your drainage system. R.H. Moore helps Florida project teams compare manufactured separators, source alternatives and develop custom configurations around the project’s hydraulic, installation and maintenance requirements.

Start With the Treatment Objective

Capture Pollutants at a Defined Point

Hydrodynamic separation uses controlled flow and physical separation to collect pollutants from stormwater. Depending on the configuration, systems can combine settling, vortex action, screening and floatables retention.

Sediment & Solids

Define the particle sizes and loading relevant to the site. Evaluate performance evidence against those conditions.

Trash & Floatables

Identify the debris that needs to be captured and how it will be retained and removed.

Oils & Attached Pollutants

Review the selected system’s capabilities for free oils and pollutants attached to sediment. Dissolved constituents may require additional treatment.

Support for Your Role

From Design Questions to Field Decisions

Engineers & Specifiers

Bring the design criteria, hydraulic information and specification. RHM can help organize system comparisons and manufacturer documentation.

Contractors & Estimators

Bring plans, dimensions and access constraints. We can help clarify configuration, sourcing and pricing inputs.

Owners & Municipalities

Bring the water-quality objective and maintenance expectations. Include service access and long-term responsibilities in the review.

Compare the Approaches

Different Internal Designs. A Shared Selection Process.

Vortex Separators

Rotating flow and internal components direct sediment toward a collection zone while retaining floatables. Review the model’s hydraulic and storage characteristics.

Baffle Box Systems

Chambers, baffles and screens can separate sediment and debris into collection areas. Some configurations hold organic material above standing water.

Screen-Assisted Systems

Screens can supplement separation to capture defined debris sizes. Confirm screen opening, loading, bypass behavior and cleaning requirements.

These are design approaches rather than interchangeable performance classes. Select the actual assembly using its evidence, site fit and acceptance requirements.

Start With the Requirements

Standard Product, Sourced Alternative or Custom Solution

The best fit may be an established manufactured system, another available configuration or a custom approach. RHM can help develop the scope and coordinate sourcing, fabrication and technical review with the appropriate project partners.

Compare Manufactured Systems

Review established options against the treatment objective, available head, footprint, pipe geometry and maintenance plan.

Find the Right Alternative

Where a specified arrangement does not fit, RHM can help source alternatives and assemble the information needed for an equivalency review.

Develop a Custom Configuration

For unusual connections, constrained layouts or specific capture needs, work with RHM to define the concept and coordinate drawings, fabrication requirements and supporting documentation.

Custom work needs a defined design basis. Changes to geometry, internals or flow routing require review; an existing product’s test results or approvals do not automatically apply to a modified assembly.

Product Knowledge Without a Single-System Approach

Compare Brands in the Context of the Project

RHM’s approach starts with your requirements and draws on multiple product and sourcing options. Examples discussed in this category include Downstream Defender® vortex separation and the Nutrient Separating Baffle Box® (NSBB®) screening-and-settling approach.

Defined Product Configuration

Identify the exact system and components being evaluated. Brand recognition alone does not establish capacity or fit.

Practical Sourcing

Ask RHM to review availability, installation needs and alternatives for the project location and schedule.

A Clear Comparison

Compare treatment basis, hydraulic impact, storage, maintenance and acceptance documentation on consistent terms.

Have a named product in your plans or an alternative you want evaluated? Send the specification and drawings so RHM can organize the review.

Put Separation in the Treatment Train

Protect the Practices Downstream

Hydrodynamic separators are used in constrained sites, end-of-pipe treatment and pretreatment ahead of storage or other water-quality practices. Define the separator’s role within the overall drainage strategy.

Development & Retrofit

Review the available space and elevations in commercial, residential, roadway or industrial drainage layouts.

Before Storage

Evaluate sediment and debris capture ahead of detention or reuse infrastructure, with separate access for each maintenance task.

Before Further Treatment

Coordinate the separator with downstream filtration, biofiltration or other processes where the water-quality objective needs more than physical separation.

Select the Complete System

Six Questions That Shape the Recommendation

What Needs Removal?

Identify sediment characteristics, trash, oils and any nutrient or metal objectives. Distinguish particulate from dissolved targets.

What Flow Needs Treatment?

Provide water-quality and peak flows. Confirm the criteria used for treatment ratings and larger-event routing.

What Hydraulic Head Is Available?

Show pipe inverts, water levels, tailwater and allowable headloss. Review on-line or off-line arrangements as appropriate.

What Fits the Site?

Provide available footprint, utilities, ground conditions, cover, surface loads and connection geometry.

How Will It Be Maintained?

Show access openings, equipment approach and expected loading. Compare storage and cleaning needs.

What Evidence Is Required?

Identify the reviewing authority and specification. Obtain current documentation for the exact proposed assembly.

Make the Recommendation Reviewable

Ask for Evidence That Matches the Application

Performance Documentation

Request applicable testing and verification. Check particle distribution, flow conditions and tested configuration.

Comparable Experience

Ask for relevant manufacturer references or documented project examples. Compare site constraints and operating conditions.

Project-Specific Drawings

Review the selected arrangement, dimensions, access and connections. Custom assemblies need their own documented acceptance basis.

RHM can help organize these materials for the project team. Comparable experience supports the discussion; final suitability depends on the actual installation.

From First Review to Supply

A Practical Path to a Recommendation

01 / Send the Conditions

Share plans, location, flows, elevations, pollutant targets and available space. Include the specification and schedule.

02 / Compare the Options

Review standard systems, sourcing alternatives and any custom needs with RHM and the project’s design team.

03 / Resolve the Details

Coordinate configuration, supporting evidence, installation requirements and acceptance before ordering.

04 / Confirm the Scope

Finalize quantities, delivery requirements and pricing. Include maintenance information in the owner handover.

Before You Specify

Hydrodynamic Separation FAQs

Is hydrodynamic separation a single product?

No. It is a treatment category encompassing different separator designs and configurations. RHM can help compare options for the project.

Can RHM help with a custom solution?

Yes. Bring the requirements and constraints so RHM can help develop the scope, source components and coordinate fabrication and technical review as needed.

Are all separators equivalent?

No. Internal design, particle capture, flow behavior, storage and maintenance requirements vary. Compare the specific assemblies and documentation.

Can separation remove dissolved nutrients?

Do not assume it can. Identify the target nutrient form and determine whether additional treatment is required.

Can I substitute a different brand?

Substitutions require review against the specification, performance basis, hydraulic fit and acceptance requirements. RHM can help assemble the comparison.

What should I send for a quote?

Provide Florida location, plans, flows, elevations, pipe layout, treatment objectives, required documents and delivery timing. If information is incomplete, send what is available for an initial review.

Bring Us the Stormwater Challenge

Find the Right Separation Approach With RHM

Whether your plans name a product or the solution is still taking shape, share the site conditions with R.H. Moore. We can help organize the options, coordinate the technical information and develop a supply or custom-solution scope for pricing.